Every module on this site is quoted at ±0.01 mm. That figure is measured in our assembly bay, on a granite plate, with the module bolted to a face we control. It is a statement about the module, not about the machine it ends up in.
Between our plate and your tool tip there are five joints. Each one can spend the accuracy you paid for, and none of them is covered by the datasheet. This page is about those five joints.
All five share a pattern: they are invisible at the module, obvious at the part, and they are almost always diagnosed as a module fault first.
A coupling that is radially offset by 0.05 mm turns a smooth rotation into a once-per-rev wobble. Across a 20 mm coupling length that offset is 0.14° of angular error, and it repeats at exactly the screw speed. The part shows a periodic mark; the operator reports "screw backlash".
The measurement is simple and almost never done. Mount a dial indicator on the motor shaft and sweep the coupling hub on the screw side, then repeat with the indicator on the screw and the stylus on the motor hub. Radial runout is the first number, angular misalignment the second. Both should be read before the coupling is finally tightened, not after.
A flexible coupling absorbs misalignment; it does not remove it. The restoring force the coupling generates becomes a radial load on the screw support bearing and on the motor bearing, and that load reverses every revolution. This is why a machine that measures fine cold develops a mark after two hours of running.
Fix it by moving the motor, not by choosing a softer coupling. A softer coupling hides the symptom and moves the failure into the bearing.
Four screws clamp a flange; they do not locate it. A Ø5.5 clearance hole for an M5 screw carries 0.5 mm of total play, enough to shift the motor nose by a quarter of a millimetre in any direction - an order of magnitude more than the accuracy of the module behind it. The part that locates the motor is the spigot, the raised boss machined into the flange face.
Our mounting flanges are drawn with the spigot toleranced and the fixing holes plain, because that is the only arrangement that works. On the 750 W plate the spigot is Ø70 +0.06/+0.02; on the 100 W plate it is Ø30 +0.05/+0.02. The band is deliberately narrow: wide enough to slide on by hand, tight enough that the motor cannot move once seated. If you are matching a motor whose pilot boss is not a standard frame, the flange has to be cut to that boss rather than to the standard - which is why we machine these in-house. See servo motor mounting flanges for the drawing set.
Check squareness with the indicator on the motor face and the stylus on the flange face, sweeping a full revolution. If the motor was clamped by its screws before the spigot was fully seated, the reading will show it, and no amount of coupling alignment will correct it.
This one announces itself as heat. The stage runs free at both ends of travel and stiffens in the middle, or the motor current climbs over a long move and settles again. What is happening is that the ball nut and the carriage are being forced to describe two slightly different lines, and the difference is absorbed by preload.
Push the carriage by hand through the full stroke before the motor is connected. It should feel the same everywhere. Then mount an indicator on the carriage and sweep the side face of the rail; repeat on the screw support housing. Any variation between the two readings is the error you are looking for.
The order of assembly matters more than the shimming. Fix the rail first, because it defines the line; then bring the screw support to the rail, not the rail to the screw. On a vertical axis this error compounds with gravity and shows up as a drop at the top of travel - the sizing logic for that case is covered in vertical Z-axis module sizing.
Belt stages are where "tight enough" does the most damage. Too loose and the teeth skip under acceleration, which looks identical to lost steps. Too tight and the load goes straight into the motor rear bearing and the idler, and the stage gets quieter right before it gets loud.
Measure it instead of feeling it. Pluck the belt at mid-span and read the frequency with a phone app, or deflect the belt a fixed distance at mid-span and read the force with a gauge. Either method gives you a number you can repeat next month; a thumb does not.
Set tension with the motor loose in its slots, then lock the motor and re-check. The slotted boss on our stepper flanges exists for exactly this adjustment - the slot is travel, not a machining leftover. Pulley geometry and the reduction each tooth count gives you are on the synchronous pulley page.
This is the one that survives every other correction. The module is straight, the flange is square, the coupling is aligned, and the part is still out. The module has been bolted to a plate that is not flat, and the housing has been pulled into the shape of that plate.
A straight edge and a feeler gauge across the mounting face will find it in a minute. On a machined plate the reading should be barely detectable; on a welded frame it usually is not. If the plate is out, shim under the module at the fixing points until the straight edge sits clean, or machine the face. Forcing the housing flat transfers the error into the preload, and preload cannot be recovered afterwards.
Multi-axis builds inherit this error twice, because each axis is referenced to the one below it. How those errors add up is covered in building XY, XY+Z and gantry axes.
When a machine misses its number, the module is the last thing to blame, not the first. Work backwards from what the part looks like:
| What you see | Most likely joint | Measure this first |
|---|---|---|
| Periodic mark at screw pitch | Coupling offset | Radial runout at both coupling hubs |
| Error grows along one end of travel | Rail and screw not parallel | Carriage drag by hand, full stroke |
| Fine cold, drifts after an hour | Coupling load on bearings | Bearing temperature, then runout again |
| Backlash that appears only under load | Belt tension too low | Span frequency or deflection force |
| Error everywhere, evenly | Base plate flatness | Straight edge and feeler gauge across the face |
| Square in X, out in Y | Flange not seated on spigot | Motor face to flange face, full revolution |
None of these six symptoms is fixed by replacing the module. Five of them are fixed with a dial indicator and an hour.
Coupling radial and angular runout read at both hubs, before final tightening.
Motor seated on the spigot by hand, then clamped - never clamped into place.
Carriage pushed through full stroke by hand with the motor disconnected; drag constant.
Belt tension recorded as a number, not a feel, and written into the machine log.
Mounting face checked with a straight edge before the module goes on, not after.
If all five are done and the part is still out, then it is worth looking at the module. That is the point at which the ball screw module range and its tolerances become the right conversation.